Hv/LV/Mv Electric PC/Mcc Power Distribution Equipment Ggd Switchgear

Hv/LV/Mv Electric PC/Mcc Power Distribution Equipment Ggd Switchgear

Overview PRODUCT DETAILS GGD type low voltage fixed switchgear is suitable for power users such as power plant substatio
Overview
Basic Info.
Model NO. GGD
Transport Package Wooden
Specification 800*1500*2300
Trademark Zhegui Electric
Origin Zhejiang, China
HS Code 8537209000
Production Capacity 10pieces/Week
Product Description

Hv/LV/Mv Electric PC/Mcc Power Distribution Equipment Ggd Switchgear

PRODUCT DETAILS

GGD type low voltage fixed switchgear is suitable for power users such as power plant substation,
industrial and mining enterprises as power conversion, distribution and control of power, lighting and distribution equipment inpower distribution system with AC 50Hz, rated working voltage 380V and rated current up to 3150A.
The product has high breaking capacity, rated short-time tolerance current up to 50kA.The line scheme has the characteristics of clever words, convenient combination, strong practicability and novel structure.This product is one of the representative products of the assembled and fixed panel switchgear in China.
This product conforms to: GB7251 "low voltage switchgear and control equipment", IEC439 "low voltage switchgear and controlequipment" and other standards.

Hv/LV/Mv Electric PC/Mcc Power Distribution Equipment Ggd Switchgear


TECHNICAL PARAMETER
modelnominal voltage(V) rated current(A)Rated short circuit breaking currentRated short circuit tolerance currentRated peak tolerable current
GGD-1000-153801000151530
600(630)
400
GGD-1600-303801500(1600)303063
1000
600
GGD-31500-5038031505050105
2500
2000

Hv/LV/Mv Electric PC/Mcc Power Distribution Equipment Ggd Switchgear

THE USE OF CONDITIONS

1. Ambient temperature
2. Altitude
3. Relative humidity2000m and below.Not more than 50% at a maximum temperature of +40° C, and greater relative humidity is allowed at lower temperatures:(e.g. 90% at +20P) should be taken into account due to A change in temperature may have an occasional effect on condensation.
4. The inclination between the equipment and the vertical plane shall not exceed 5.
5. The equipment should be installed in the place where there is no severe vibration and impact, and where the electrical
components are not corroded.
Note: if If the above conditions cannot be met, the user can negotiate with the company to solve the special requirements.

COMPANY INFORMATION

Hv/LV/Mv Electric PC/Mcc Power Distribution Equipment Ggd Switchgear

WOORKSHOP

Hv/LV/Mv Electric PC/Mcc Power Distribution Equipment Ggd Switchgear

Contact UsCertificationsSHIPPING PAYMEANT